{"id":6471,"date":"2026-11-26T02:10:40","date_gmt":"2026-11-26T02:10:40","guid":{"rendered":"https:\/\/grandgelgumi.com\/?p=6471"},"modified":"2026-11-26T02:10:40","modified_gmt":"2026-11-26T02:10:40","slug":"hausner-ratio-carr-index","status":"publish","type":"post","link":"https:\/\/grandgelgumi.com\/ko\/hausner-ratio-carr-index\/","title":{"rendered":"Hausner Ratio and Carr Index: Powder Flow in Tableting"},"content":{"rendered":"\n<style>.gel-hausner{color:#111518;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.gel-hausner p,.gel-hausner li,.gel-hausner td,.gel-hausner th,.gel-hausner caption{color:#111518}\n.gel-hausner p{margin:0 0 1.1em}\n.gel-hausner h2{color:#111518;font-size:28px;font-weight:700;line-height:1.35;margin:1.9em 0 .75em;scroll-margin-top:140px}\n.gel-hausner h3{color:#111518;font-size:22px;font-weight:700;line-height:1.4;margin:1.4em 0 .65em;scroll-margin-top:140px}\n.gel-hausner ul,.gel-hausner ol{padding-left:1.4em;margin:0 0 1.25em}\n.gel-hausner li{margin-bottom:.45em}\n.gel-hausner a{color:#bd3f0b;text-decoration:underline;text-underline-offset:3px}\n.gel-hausner a:hover{color:#8a2d08}\n.gel-hausner nav{padding:20px 24px;margin:1.4em 0 1.75em;background:#fafafa;border:1px solid #e5e7eb;border-radius:4px}\n.gel-hausner nav p{margin:0 0 12px}\n.gel-hausner nav ol{display:grid;grid-template-columns:minmax(0,1fr) minmax(0,1fr);gap:4px 28px;margin:0;padding-left:1.4em;font-size:15px;line-height:1.55}\n.gel-hausner nav li{padding-left:2px;margin-bottom:6px}\n.gel-hausner nav a{color:#111518;text-decoration:none}\n.gel-hausner nav a:hover{text-decoration:underline;color:#bd3f0b}\n.gel-hausner .gel-table-wrap{max-width:100%;overflow-x:auto;margin:1.25em 0 1.75em}\n.gel-hausner table{width:100%;border-collapse:collapse;text-align:left;margin:0}\n.gel-hausner caption{text-align:left;font-size:14px;line-height:1.5;padding:0 0 10px}\n.gel-hausner th,.gel-hausner td{padding:12px 14px;border:1px solid #e5e7eb;vertical-align:top;line-height:1.6;font-size:15px}\n.gel-hausner thead th{background:#fff4ed;font-weight:700}\n.gel-hausner section[aria-labelledby=\"faq\"] details{margin:0;border-bottom:1px solid #e9ebec;background:#fff}\n.gel-hausner section[aria-labelledby=\"faq\"] details[open]{background:#fffaf6}\n.gel-hausner section[aria-labelledby=\"faq\"] summary{display:flex;align-items:center;justify-content:space-between;gap:20px;min-height:64px;padding:18px 20px;list-style:none;cursor:pointer;color:#111518;font-size:18px;font-weight:600;line-height:1.5}\n.gel-hausner section[aria-labelledby=\"faq\"] summary::-webkit-details-marker{display:none}\n.gel-hausner section[aria-labelledby=\"faq\"] summary::marker{content:\"\"}\n.gel-hausner section[aria-labelledby=\"faq\"] summary::after{content:\"+\";flex:0 0 auto;color:#f05e22;font:400 26px\/1 Arial,sans-serif}\n.gel-hausner section[aria-labelledby=\"faq\"] details[open] summary::after{content:\"\u2212\"}\n.gel-hausner section[aria-labelledby=\"faq\"] summary:focus-visible{outline:2px solid #f05e22;outline-offset:-4px}\n.gel-hausner section[aria-labelledby=\"faq\"] details>p{margin:0;padding:0 54px 22px 20px;color:#111518}\n.gel-hausner section[aria-labelledby=\"technical-references\"] ol{font-size:15px;line-height:1.65}\n@media(max-width:767px){.gel-hausner{font-size:16px;line-height:1.75}.gel-hausner h2{font-size:24px;scroll-margin-top:115px}.gel-hausner h3{font-size:20px}.gel-hausner nav{padding:18px}.gel-hausner nav ol{grid-template-columns:minmax(0,1fr)}.gel-hausner .gel-table-wrap table{min-width:560px}.gel-hausner th,.gel-hausner td{padding:10px;font-size:14px}.gel-hausner section[aria-labelledby=\"faq\"] summary{min-height:56px;padding:16px 14px;gap:12px;font-size:16px}.gel-hausner section[aria-labelledby=\"faq\"] details>p{padding:0 42px 20px 14px}}\n\n\/* Match the established GEL article typography and accordion treatment. *\/\n.gel-hausner{line-height:1.65}\n.gel-hausner p{margin:0 0 1.5em}\n.gel-hausner h2{font-size:32px;font-weight:700;line-height:1.5;margin:1.65em 0 .6em;scroll-margin-top:160px}\n.gel-hausner h3{font-size:24px;font-weight:600;line-height:1.5;margin:1.4em 0 .65em;scroll-margin-top:160px}\n.gel-hausner section[aria-labelledby=\"key-takeaways\"] ul{padding-left:1.25em}\n.gel-hausner section[aria-labelledby=\"key-takeaways\"] li{margin-bottom:10px;line-height:1.75}\n.gel-hausner nav[aria-label=\"Table of Contents\"]{padding:16px 22px;margin:1.5em 0 2em;background:#f9f9f9;border:1px solid #dfe3e6;border-radius:4px}\n.gel-hausner .gel-article-toc{margin:0;padding:0;border:0;background:transparent}\n.gel-hausner .gel-article-toc>summary{display:flex;align-items:center;justify-content:space-between;gap:16px;min-height:36px;padding:0;list-style:none;cursor:pointer;color:#111518;font-size:18px;font-weight:700;line-height:1.5}\n.gel-hausner .gel-article-toc>summary::-webkit-details-marker{display:none}\n.gel-hausner .gel-article-toc>summary::marker{content:\"\"}\n.gel-hausner .gel-article-toc>summary::after{content:\"+\";flex:0 0 24px;text-align:center;color:#455059;font:400 24px\/1 Arial,sans-serif}\n.gel-hausner .gel-article-toc[open]>summary::after{content:\"\u2212\"}\n.gel-hausner .gel-article-toc>summary:focus-visible{outline:2px solid #f05e22;outline-offset:4px}\n.gel-hausner nav .gel-article-toc>ol{display:block;grid-template-columns:none;margin:12px 0 0;padding-left:1.65em;list-style:decimal;font-size:16px;font-weight:500;line-height:1.6}\n.gel-hausner nav .gel-article-toc>ol>li{margin:0;padding-left:3px;line-height:1.6}\n.gel-hausner nav .gel-article-toc>ol>li::marker{color:#455059;font-variant-numeric:tabular-nums}\n.gel-hausner nav .gel-article-toc a{display:block;padding:4px 0;color:#111518;text-decoration:none;overflow-wrap:break-word}\n.gel-hausner nav .gel-article-toc a:hover{color:#b34818;text-decoration:underline}\n.gel-hausner nav .gel-article-toc a:focus-visible{outline:2px solid #f05e22;outline-offset:2px}\n.gel-hausner thead th{background:#f9f9f9;font-weight:600}\n.gel-hausner tbody th{font-weight:600}\n.gel-hausner section[aria-labelledby=\"faq\"] details{border-left:3px solid transparent}\n.gel-hausner section[aria-labelledby=\"faq\"] details:first-of-type{border-top:1px solid #e9ebec}\n.gel-hausner section[aria-labelledby=\"faq\"] details[open]{border-left-color:#f05e22;background:#fffaf6}\n.gel-hausner section[aria-labelledby=\"faq\"] summary{padding:18px 22px}\n.gel-hausner section[aria-labelledby=\"faq\"] summary:hover{color:#b34818}\n.gel-hausner section[aria-labelledby=\"faq\"] details>p{padding:0 56px 22px 22px;margin:0;font-size:16px;line-height:1.75;color:#111518}\n@media(max-width:767px){\n.gel-hausner h2{font-size:26px;line-height:1.4;scroll-margin-top:140px}\n.gel-hausner h3{font-size:22px;line-height:1.45;scroll-margin-top:140px}\n.gel-hausner nav[aria-label=\"Table of Contents\"]{padding:14px 16px}\n.gel-hausner .gel-article-toc>summary{font-size:17px}\n.gel-hausner nav .gel-article-toc>ol{font-size:15px;padding-left:1.55em}\n.gel-hausner nav .gel-article-toc a{padding:5px 0}\n.gel-hausner section[aria-labelledby=\"faq\"] summary{padding:16px 14px}\n.gel-hausner section[aria-labelledby=\"faq\"] details>p{padding:0 42px 20px 14px;font-size:15px}\n}\n.gel-hausner .gel-article-figure{width:55%;max-width:520px;margin:28px auto 36px}.gel-hausner .gel-article-figure img{display:block;width:100%;max-width:100%;height:auto;border:0;border-radius:0;box-shadow:none}@media(max-width:1024px){.gel-hausner .gel-article-figure{width:100%;max-width:520px}}\n\n\n.gel-hausner .repose-tool{border:1px solid #dfe3e6;background:#fffaf6;border-radius:8px;padding:22px 24px;margin:1.6em 0 2em}\n.gel-hausner .repose-tool h3{margin:0 0 12px;font-size:22px}\n.gel-hausner .repose-fields{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:16px;margin:18px 0}\n.gel-hausner .repose-fields label{display:block;font-size:15px;font-weight:600}\n.gel-hausner .repose-fields input{display:block;width:100%;min-width:0;padding:10px 12px;margin-top:6px;border:1px solid #cfd4d7;border-radius:4px;background:#fff;color:#111518;font:inherit;box-sizing:border-box}\n.gel-hausner .repose-fields input:focus-visible,.gel-hausner .repose-tool button:focus-visible{outline:2px solid #bd3f0b;outline-offset:2px}\n.gel-hausner .repose-tool button{padding:10px 18px;border:0;border-radius:4px;background:#bd3f0b;color:#fff;font-weight:600;cursor:pointer}\n.gel-hausner .repose-tool output{display:block;color:#bd3f0b;font-weight:700;font-size:32px;line-height:1.4;margin:12px 0}\n.gel-hausner .repose-tool p{margin:0 0 12px}\n.gel-hausner .repose-note{font-size:14px;line-height:1.6}\n.gel-hausner .repose-diagram{width:74%;max-width:580px;margin:20px auto 26px}\n.gel-hausner .repose-diagram svg{display:block;width:100%;height:auto}\n.gel-hausner .repose-formula{padding:14px 18px;margin:1.2em 0;background:#f9f9f9;font-weight:600;text-align:center;font-size:21px}\n.gel-hausner .repose-cta{background:#fff4ed;border-left:3px solid #f05e22;padding:20px 24px;margin:1.5em 0}\n.gel-hausner .repose-cta p:last-child{margin-bottom:0}\n@media(max-width:767px){.gel-hausner .repose-tool{padding:16px}.gel-hausner .repose-fields{grid-template-columns:1fr}.gel-hausner .repose-diagram{width:100%}.gel-hausner .repose-cta{padding:16px}}\n\n\n.gel-hausner .repose-tool .hr-results{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px;margin:16px 0}\n.gel-hausner .hr-result{background:#fff;border:1px solid #e5e7eb;border-radius:5px;padding:12px 16px}\n.gel-hausner .hr-result span{font-size:15px;font-weight:600;color:#455059}\n.gel-hausner .hr-result output{margin:5px 0;font-size:30px}\n.gel-hausner .hr-unit{display:block;font-size:15px;font-weight:600;margin:12px 0}\n.gel-hausner .hr-unit select{display:block;width:100%;max-width:320px;border:1px solid #cfd4d7;border-radius:4px;padding:10px 12px;background:#fff;color:#111518;font:inherit;margin-top:5px}\n.gel-hausner .hr-error{color:#a93b15;min-height:1.5em;margin:8px 0}\n.gel-hausner .hr-reset{background:#fff!important;color:#bd3f0b!important;border:1px solid #bd3f0b!important;margin-left:8px}\n.gel-hausner .hr-equations{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px;margin:18px 0}\n.gel-hausner .hr-equations .repose-formula{margin:0;font-size:19px;line-height:1.6}\n.gel-hausner .hr-equations small{display:block;font-size:13px;color:#455059;font-weight:600}\n@media(max-width:767px){.gel-hausner .hr-equations,.gel-hausner .repose-tool .hr-results{grid-template-columns:1fr}.gel-hausner .hr-result output{font-size:27px}}\n<\/style>\n<article class=\"gel-hausner\" lang=\"en-US\" aria-label=\"Hausner ratio and Carr index technical article\"><p class=\"quick-answer\"><strong>Quick Answer:<\/strong> The <strong>Hausner ratio<\/strong> is tapped bulk density divided by untapped bulk density. The <strong>Carr index<\/strong> is 100 \u00d7 (tapped density \u2212 untapped density) \/ tapped density. For densities of 0.500 and 0.625 g\/mL, the results are 1.250 and 20.00%. Both describe relative powder consolidation and help screen materials before tablet pressing.<\/p><nav aria-label=\"Table of Contents\"><details class=\"gel-article-toc\" open><summary>Table of Contents<\/summary><ol><li><a href=\"#key-takeaways\">Key Takeaways<\/a><\/li><li><a href=\"#what-is-hausner-ratio\">What Is the Hausner Ratio?<\/a><\/li><li><a href=\"#what-is-carr-index\">What Is the Carr Index?<\/a><\/li><li><a href=\"#formulas\">Hausner Ratio Formula and Carr Index Formula<\/a><\/li><li><a href=\"#example\">How to Calculate Hausner Ratio and Carr Index<\/a><\/li><li><a href=\"#interpretation\">Hausner Ratio and Carr Index Flowability Chart<\/a><\/li><li><a href=\"#measurement\">How to Obtain Comparable Test Results<\/a><\/li><li><a href=\"#same-index\">Why Identical Hausner Ratios Can Produce Different Fill Weights<\/a><\/li><li><a href=\"#press-application\">How Hausner Ratio Relates to Rotary Tablet Press Performance<\/a><\/li><li><a href=\"#comparison\">Hausner Ratio vs. Angle of Repose and Other Flow Tests<\/a><\/li><li><a href=\"#trial-checklist\">Powder Flow Records Before a Tablet Press Trial<\/a><\/li><li><a href=\"#faq\">Frequently Asked Questions<\/a><\/li><li><a href=\"#conclusion\">Conclusion<\/a><\/li><li><a href=\"#technical-references\">Technical References<\/a><\/li><\/ol><\/details><\/nav><section aria-labelledby=\"key-takeaways\"><h2 id=\"key-takeaways\"><span class=\"ez-toc-section\" id=\"Key_Takeaways\"><\/span>Key Takeaways<span class=\"ez-toc-section-end\"><\/span><\/h2><ul><li><strong>Hausner ratio (HR):<\/strong> Divide tapped bulk density by untapped bulk density.<\/li><li><strong>Carr index (CI):<\/strong> Express the decrease in bulk volume after tapping as a percentage of the initial volume.<\/li><li><strong>Relationship:<\/strong> Both indicators use the same paired measurement. They are mathematically related and do not provide two independent confirmations of flow.<\/li><li><strong>Interpretation:<\/strong> Lower values generally indicate less consolidation in comparable tests. No single HR or CI value proves suitable tablet press performance.<\/li><li><strong>Production:<\/strong> Retain the actual density values alongside the indices when planning die filling and tablet weight investigations.<\/li><\/ul><\/section>\n<section aria-labelledby=\"what-is-hausner-ratio\"><h2 id=\"what-is-hausner-ratio\"><span class=\"ez-toc-section\" id=\"What_Is_the_Hausner_Ratio\"><\/span>What Is the Hausner Ratio?<span class=\"ez-toc-section-end\"><\/span><\/h2><p>The Hausner ratio compares the density of a powder bed after tapping with its original loose bulk density. It is dimensionless because both values use the same units. A ratio near 1 means that the measured bed volume changed relatively little; a larger value indicates more consolidation during the specified tapping procedure.<\/p><p>For pharmaceutical and nutraceutical teams, the ratio is an indirect indicator of material handling behavior. Particle geometry, fines, cohesion, moisture and the measurement procedure can all influence the result. USP General Chapter &lang;1174&rang; discusses the Hausner ratio together with the compressibility index as one approach to evaluating powder flow. <sup><a href=\"#ref-usp\">[1]<\/a><\/sup><\/p><\/section>\n<section aria-labelledby=\"what-is-carr-index\"><h2 id=\"what-is-carr-index\"><span class=\"ez-toc-section\" id=\"What_Is_the_Carr_Index\"><\/span>What Is the Carr Index?<span class=\"ez-toc-section-end\"><\/span><\/h2><p>The Carr index, also called Carr&#8217;s compressibility index, expresses relative powder bed consolidation as a percentage. A 100 g sample that settles from 200 mL to 160 mL occupies 40 mL less apparent bulk volume, a reduction of 20%. In this illustrative calculation, the powder mass remains unchanged.<\/p><p>Compressibility in this context refers to the change observed during tapping. It does not measure the force needed to compact a blend into a tablet, the bonding strength of particles or the breaking force of the finished tablet. Avoid treating a flow index as a direct measure of tabletability.<\/p><\/section>\n<section aria-labelledby=\"formulas\"><h2 id=\"formulas\"><span class=\"ez-toc-section\" id=\"Hausner_Ratio_Formula_and_Carr_Index_Formula\"><\/span>Hausner Ratio Formula and Carr Index Formula<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Use values measured on the same material portion. Let \u03c1<sub>b<\/sub> denote untapped bulk density, \u03c1<sub>t<\/sub> tapped bulk density, V<sub>0<\/sub> untapped volume and V<sub>f<\/sub> final tapped volume.<\/p><div class=\"hr-equations\"><div class=\"repose-formula\"><small>Hausner ratio<\/small>HR = \u03c1<sub>t<\/sub> \/ \u03c1<sub>b<\/sub><br>HR = V<sub>0<\/sub> \/ V<sub>f<\/sub><\/div><div class=\"repose-formula\"><small>Carr index (%)<\/small>CI = 100 \u00d7 (\u03c1<sub>t<\/sub> \u2212 \u03c1<sub>b<\/sub>) \/ \u03c1<sub>t<\/sub><br>CI = 100 \u00d7 (V<sub>0<\/sub> \u2212 V<sub>f<\/sub>) \/ V<sub>0<\/sub><\/div><\/div><p>These equivalent forms follow from density = mass \/ volume when the same sample retains its mass. <sup><a href=\"#ref-usp\">[1]<\/a><\/sup> A frequent calculation error is dividing the density difference by untapped density instead of tapped density. That calculation produces a different percentage.<\/p><h3>How the two indices are related<\/h3><div class=\"repose-formula\">CI = 100 \u00d7 (1 \u2212 1 \/ HR)<br>HR = 1 \/ (1 \u2212 CI \/ 100)<\/div><p>Keep full calculation precision until reporting the final values. Two results derived from the same unrounded density data must satisfy this relationship, subject to rounding. A discrepancy may reveal an input, unit or formula error. Neither index is an additional independent measurement.<\/p><\/section>\n<section aria-labelledby=\"example\"><h2 id=\"example\"><span class=\"ez-toc-section\" id=\"How_to_Calculate_Hausner_Ratio_and_Carr_Index\"><\/span>How to Calculate Hausner Ratio and Carr Index<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Continue the illustrative 100 g powder example from our <a href=\"https:\/\/grandgelgumi.com\/tap-density\/\">Tap Density guide<\/a>. The same sample occupies 200 mL before tapping and 160 mL at the documented final reading. The figures below are mathematical examples, not measurements from a GRAND customer or equipment trial.<\/p><figure class=\"repose-diagram\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 660 358\" role=\"img\" aria-labelledby=\"hr-fig-title hr-fig-desc\"><title id=\"hr-fig-title\">Same powder sample before and after tapping<\/title><desc id=\"hr-fig-desc\">Two graduated cylinders show 100 grams of powder, initially occupying 200 milliliters and finally occupying 160 milliliters. The powder mass is unchanged. The final bed is shorter because the particles pack more closely.<\/desc><defs><linearGradient id=\"hr-glass\" x1=\"0\" x2=\"1\"><stop stop-color=\"#c2d7df\" stop-opacity=\".65\"\/><stop offset=\".22\" stop-color=\"#fff\" stop-opacity=\".9\"\/><stop offset=\".64\" stop-color=\"#e5f1f5\" stop-opacity=\".35\"\/><stop offset=\"1\" stop-color=\"#afc1cb\" stop-opacity=\".65\"\/><\/linearGradient><linearGradient id=\"hr-powder\" x1=\"0\" y1=\"0\" x2=\".1\" y2=\"1\"><stop stop-color=\"#f5e5cc\"\/><stop offset=\"1\" stop-color=\"#d6b890\"\/><\/linearGradient><pattern id=\"hr-loose\" width=\"15\" height=\"17\" patternUnits=\"userSpaceOnUse\"><circle cx=\"3\" cy=\"4\" r=\"2.3\" fill=\"#c19a6b\" opacity=\".8\"\/><circle cx=\"10\" cy=\"10\" r=\"2.7\" fill=\"#fff1da\" opacity=\".9\"\/><circle cx=\"4\" cy=\"14\" r=\"1.6\" fill=\"#b68955\" opacity=\".65\"\/><\/pattern><pattern id=\"hr-tapped\" width=\"11\" height=\"11\" patternUnits=\"userSpaceOnUse\"><circle cx=\"2.7\" cy=\"3\" r=\"2.2\" fill=\"#c19a6b\" opacity=\".8\"\/><circle cx=\"8\" cy=\"8\" r=\"2.5\" fill=\"#fff1da\" opacity=\".9\"\/><\/pattern><marker id=\"hr-arrow\" viewBox=\"0 0 10 10\" refX=\"8\" refY=\"5\" markerWidth=\"6\" markerHeight=\"6\" orient=\"auto\"><path d=\"M0 0L10 5L0 10Z\" fill=\"#d85517\"\/><\/marker><\/defs><g font-family=\"Arial,sans-serif\" text-anchor=\"middle\"><text x=\"165\" y=\"29\" fill=\"#27333b\" font-size=\"19\" font-weight=\"700\">Untapped<\/text><text x=\"495\" y=\"29\" fill=\"#27333b\" font-size=\"19\" font-weight=\"700\">Tapped<\/text><\/g><g stroke=\"#8da0aa\" stroke-width=\"1.5\"><path d=\"M114 52V272Q114 285 127 285H203Q216 285 216 272V52Z\" fill=\"url(#hr-glass)\"\/><ellipse cx=\"165\" cy=\"52\" rx=\"51\" ry=\"8\" fill=\"#f3f8fa\" stroke=\"#869aa5\"\/><ellipse cx=\"165\" cy=\"52\" rx=\"44\" ry=\"4.8\" fill=\"none\" stroke=\"#c1d0d6\"\/><rect x=\"131\" y=\"285\" width=\"68\" height=\"14\" rx=\"2\" fill=\"#c4d0d7\"\/><rect x=\"106\" y=\"298\" width=\"118\" height=\"12\" rx=\"4\" fill=\"#adbcc5\"\/><path d=\"M444 52V272Q444 285 457 285H533Q546 285 546 272V52Z\" fill=\"url(#hr-glass)\"\/><ellipse cx=\"495\" cy=\"52\" rx=\"51\" ry=\"8\" fill=\"#f3f8fa\" stroke=\"#869aa5\"\/><ellipse cx=\"495\" cy=\"52\" rx=\"44\" ry=\"4.8\" fill=\"none\" stroke=\"#c1d0d6\"\/><rect x=\"461\" y=\"285\" width=\"68\" height=\"14\" rx=\"2\" fill=\"#c4d0d7\"\/><rect x=\"436\" y=\"298\" width=\"118\" height=\"12\" rx=\"4\" fill=\"#adbcc5\"\/><\/g><path d=\"M120 104Q165 99 210 104V272Q210 279 201 279H129Q120 279 120 272Z\" fill=\"url(#hr-powder)\"\/><path d=\"M120 104Q165 99 210 104V272Q210 279 201 279H129Q120 279 120 272Z\" fill=\"url(#hr-loose)\"\/><path d=\"M450 140Q495 135 540 140V272Q540 279 531 279H459Q450 279 450 272Z\" fill=\"url(#hr-powder)\"\/><path d=\"M450 140Q495 135 540 140V272Q540 279 531 279H459Q450 279 450 272Z\" fill=\"url(#hr-tapped)\"\/><path d=\"M127 62V270M457 62V270\" stroke=\"#fff\" stroke-width=\"3\" opacity=\".8\"\/><g stroke=\"#687d88\" stroke-width=\"1.3\"><path d=\"M194 60H215M524 60H545\"\/><path d=\"M194 104H215M524 104H545\"\/><path d=\"M194 148H215M524 148H545\"\/><path d=\"M194 192H215M524 192H545\"\/><path d=\"M194 236H215M524 236H545\"\/><path d=\"M194 280H215M524 280H545\"\/><path d=\"M203 82H215M533 82H545\"\/><path d=\"M203 126H215M533 126H545\"\/><path d=\"M203 170H215M533 170H545\"\/><path d=\"M203 214H215M533 214H545\"\/><path d=\"M203 258H215M533 258H545\"\/><\/g><g font-family=\"Arial,sans-serif\" font-size=\"12\" fill=\"#4f606a\" text-anchor=\"start\"><text x=\"225\" y=\"64\">250<\/text><text x=\"555\" y=\"64\">250<\/text><text x=\"225\" y=\"108\">200<\/text><text x=\"555\" y=\"108\">200<\/text><text x=\"225\" y=\"152\">150<\/text><text x=\"555\" y=\"152\">150<\/text><text x=\"225\" y=\"196\">100<\/text><text x=\"555\" y=\"196\">100<\/text><text x=\"225\" y=\"240\">50<\/text><text x=\"555\" y=\"240\">50<\/text><text x=\"225\" y=\"284\">0<\/text><text x=\"555\" y=\"284\">0<\/text><\/g><path d=\"M118 104H263M448 140H390\" stroke=\"#d85517\" stroke-width=\"1.4\" stroke-dasharray=\"4 3\"\/><g font-family=\"Arial,sans-serif\" font-size=\"17\" font-weight=\"700\" fill=\"#bd3f0b\" text-anchor=\"middle\"><rect x=\"252\" y=\"87\" width=\"86\" height=\"31\" rx=\"4\" fill=\"#fff4ed\"\/><text x=\"295\" y=\"107\">200 mL<\/text><rect x=\"344\" y=\"122\" width=\"86\" height=\"31\" rx=\"4\" fill=\"#fff4ed\"\/><text x=\"387\" y=\"142\">160 mL<\/text><\/g><path d=\"M278 181H381\" stroke=\"#d85517\" stroke-width=\"2.4\" marker-end=\"url(#hr-arrow)\"\/><g font-family=\"Arial,sans-serif\" text-anchor=\"middle\" fill=\"#27333b\" font-weight=\"600\" font-size=\"16\"><text x=\"330\" y=\"169\">Tapping<\/text><text x=\"165\" y=\"339\">100 g<\/text><text x=\"495\" y=\"339\">100 g<\/text><\/g><\/svg><\/figure><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Worked example using a 100 g powder sample\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Input or result<\/th><th scope=\"col\">Calculation<\/th><th scope=\"col\">Value<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Sample mass<\/th><td>Same portion before and after tapping<\/td><td>100 g<\/td><\/tr><tr><th scope=\"row\">Untapped bulk density<\/th><td>100 \/ 200<\/td><td>0.500 g\/mL<\/td><\/tr><tr><th scope=\"row\">Tapped bulk density<\/th><td>100 \/ 160<\/td><td>0.625 g\/mL<\/td><\/tr><tr><th scope=\"row\">Hausner ratio<\/th><td>0.625 \/ 0.500<\/td><td>1.250<\/td><\/tr><tr><th scope=\"row\">Carr index<\/th><td>100 \u00d7 (0.625 \u2212 0.500) \/ 0.625<\/td><td>20.00%<\/td><\/tr><\/tbody><\/table><\/div><p>The volume equations produce exactly the same values: HR = 200 \/ 160 = 1.25 and CI = 100 \u00d7 (200 \u2212 160) \/ 200 = 20%. Under the referenced relative ranking these example results sit at the upper end of the fair-flow category.<\/p><div class=\"repose-tool\" id=\"gel-hausner-calculator\"><h3>Hausner Ratio and Carr Index Calculator<\/h3><p>Choose one input method. Use paired values from the same powder sample in the same units. Results update automatically as you type.<\/p><label class=\"hr-unit\" for=\"hr-mode\">Input method<select id=\"hr-mode\"><option value=\"density\">Bulk and tapped density (g\/mL)<\/option><option value=\"volume\">Untapped and tapped volume (mL)<\/option><\/select><\/label><div class=\"repose-fields\"><label for=\"hr-in-a\"><span id=\"hr-label-a\">Untapped bulk density (g\/mL)<\/span><input id=\"hr-in-a\" type=\"text\" inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" aria-describedby=\"hr-precision hr-error\" aria-invalid=\"false\" value=\"0.5\"><\/label><label for=\"hr-in-b\"><span id=\"hr-label-b\">Tapped bulk density (g\/mL)<\/span><input id=\"hr-in-b\" type=\"text\" inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" aria-describedby=\"hr-precision hr-error\" aria-invalid=\"false\" value=\"0.625\"><\/label><\/div><p class=\"repose-note\" id=\"hr-precision\">Use a decimal point, with up to 9 digits before it and 6 digits after it. Hausner ratio is shown to 3 decimal places and Carr index to 2 decimal places.<\/p><button type=\"button\" class=\"hr-reset\" id=\"hr-reset\" style=\"margin-left:0\">Reset example<\/button><div class=\"hr-results\"><div class=\"hr-result\"><span>Hausner ratio<\/span><output id=\"hr-out\" aria-live=\"polite\" for=\"hr-in-a hr-in-b\">\u2014<\/output><\/div><div class=\"hr-result\"><span>Carr index<\/span><output id=\"ci-out\" aria-live=\"polite\" for=\"hr-in-a hr-in-b\">\u2014<\/output><\/div><\/div><p class=\"hr-error\" id=\"hr-error\" role=\"status\" aria-live=\"polite\">Calculator loading. If results do not update, reload the page.<\/p><p class=\"repose-note\">Calculated values are screening indicators. Interpret them using the laboratory&#8217;s documented method and reporting rules, then verify actual feeding and tablet quality.<\/p><\/div><script>(function boot(doc,win){\n  function init(){\n    var root=doc.getElementById('gel-hausner-calculator');\n    if(!root)return false;\n    if(root.getAttribute('data-hr-ready')==='true')return true;\n    function get(id){return root.querySelector('#'+id);}\n    var mode=get('hr-mode'),a=get('hr-in-a'),b=get('hr-in-b'),o1=get('hr-out'),o2=get('ci-out'),err=get('hr-error'),la=get('hr-label-a'),lb=get('hr-label-b'),reset=get('hr-reset');\n    if(!mode||!a||!b||!o1||!o2||!err||!la||!lb||!reset)return false;\n    function setInvalid(field,state){field.setAttribute('aria-invalid',state?'true':'false');}\n    function invalid(message,badA,badB){\n      o1.textContent='\u2014';\n      o2.textContent='\u2014';\n      err.textContent=message;\n      setInvalid(a,badA);\n      setInvalid(b,badB);\n    }\n    function read(field){\n      var value=field.value.trim();\n      if(!value)return {error:'Enter two positive values.'};\n      if(!\/^(?:[0-9]{1,9}(?:\\.[0-9]{0,6})?|\\.[0-9]{1,6})$\/.test(value))return {error:'Use positive decimal numbers with no more than 9 digits before the decimal point and 6 after it. Do not use letters or exponent notation.'};\n      var n=Number(value);\n      if(!Number.isFinite(n)||!(n>0))return {error:'Enter two positive values.'};\n      return {number:n};\n    }\n    function calc(){\n      var av=read(a),bv=read(b);\n      if(av.error||bv.error){invalid(av.error||bv.error,!!av.error,!!bv.error);return;}\n      var x=av.number,y=bv.number;\n      var density=mode.value==='density';\n      if(density){\n        if(x>y){invalid('Tapped density must not be lower than untapped density. Check the measurements.',true,true);return;}\n      }else{\n        if(y>x){invalid('Final tapped volume must not exceed initial volume. Check the measurements.',true,true);return;}\n      }\n      var hr=density?y\/x:x\/y;\n      var ci=density?(y-x)\/y*100:(x-y)\/x*100;\n      if(!Number.isFinite(hr)||!Number.isFinite(ci)){invalid('The values are outside the calculation range.',true,true);return;}\n      o1.textContent=hr.toFixed(3);\n      o2.textContent=ci.toFixed(2)+'%';\n      err.textContent='';\n      setInvalid(a,false);\n      setInvalid(b,false);\n    }\n    function labels(){\n      var density=mode.value==='density';\n      la.textContent=density?'Untapped bulk density (g\/mL)':'Untapped bulk volume (mL)';\n      lb.textContent=density?'Tapped bulk density (g\/mL)':'Final tapped bulk volume (mL)';\n    }\n    function defaults(){\n      labels();\n      var density=mode.value==='density';\n      a.value=density?'0.5':'200';\n      b.value=density?'0.625':'160';\n      calc();\n    }\n    function refresh(){labels();calc();}\n    mode.addEventListener('change',defaults);\n    reset.addEventListener('click',defaults);\n    a.addEventListener('input',calc);\n    b.addEventListener('input',calc);\n    a.addEventListener('change',calc);\n    b.addEventListener('change',calc);\n    win.addEventListener('pageshow',refresh);\n    root.setAttribute('data-hr-ready','true');\n    refresh();\n    return true;\n  }\n  if(!init()){doc.addEventListener('DOMContentLoaded',init,{once:true});}\n})(document,window);<\/script><\/section>\n<section aria-labelledby=\"interpretation\"><h2 id=\"interpretation\"><span class=\"ez-toc-section\" id=\"Hausner_Ratio_and_Carr_Index_Flowability_Chart\"><\/span>Hausner Ratio and Carr Index Flowability Chart<span class=\"ez-toc-section-end\"><\/span><\/h2><p>USP &lang;1174&rang; includes a widely used descriptive ranking for the two indicators. Use the table to communicate relative flow characteristics, not as an automatic batch-release specification. <sup><a href=\"#ref-usp\">[1]<\/a><\/sup><\/p><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Relative flow ranking by Carr index and Hausner ratio\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Carr index (%)<\/th><th scope=\"col\">Hausner ratio<\/th><th scope=\"col\">Relative flow<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">1\u201310<\/th><td>1.00\u20131.11<\/td><td>Excellent<\/td><\/tr><tr><th scope=\"row\">11\u201315<\/th><td>1.12\u20131.18<\/td><td>Good<\/td><\/tr><tr><th scope=\"row\">16\u201320<\/th><td>1.19\u20131.25<\/td><td>Fair<\/td><\/tr><tr><th scope=\"row\">21\u201325<\/th><td>1.26\u20131.34<\/td><td>Passable<\/td><\/tr><tr><th scope=\"row\">26\u201331<\/th><td>1.35\u20131.45<\/td><td>Poor<\/td><\/tr><tr><th scope=\"row\">32\u201337<\/th><td>1.46\u20131.59<\/td><td>Very poor<\/td><\/tr><tr><th scope=\"row\">Above 38<\/th><td>Above 1.60<\/td><td>Very, very poor<\/td><\/tr><\/tbody><\/table><\/div><p>The table follows the USP chapter effective May 1, 2024, including gaps at certain boundaries. A zero CI is possible if the measured volume is unchanged; report it as calculated rather than extending the table. Apply your laboratory\u2019s documented reporting and rounding rules. If rounded values fall into different categories, retain both numerical results and explain the discrepancy.<\/p><h3>Compare illustrative powder readings<\/h3><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Illustrative results for three powder samples\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Bulk density (g\/mL)<\/th><th scope=\"col\">Tapped density (g\/mL)<\/th><th scope=\"col\">HR<\/th><th scope=\"col\">CI<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">0.500<\/th><td>0.550<\/td><td>1.100<\/td><td>9.09%<\/td><\/tr><tr><th scope=\"row\">0.500<\/th><td>0.625<\/td><td>1.250<\/td><td>20.00%<\/td><\/tr><tr><th scope=\"row\">0.400<\/th><td>0.600<\/td><td>1.500<\/td><td>33.33%<\/td><\/tr><\/tbody><\/table><\/div><p>A higher index can help prioritize an investigation into cohesion or packing variability, but the actual flow through a hopper or feed frame must be evaluated separately.<\/p><\/section>\n<section aria-labelledby=\"measurement\"><h2 id=\"measurement\"><span class=\"ez-toc-section\" id=\"How_to_Obtain_Comparable_Test_Results\"><\/span>How to Obtain Comparable Test Results<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Start with the laboratory&#8217;s established bulk and tapped density method. Record the initial and final volume of a representative powder portion, or record the corresponding densities calculated from that portion. Avoid mixing an untapped reading from one sample with a tapped reading from another.<\/p><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Measurement controls for comparable powder flow indices\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Control point<\/th><th scope=\"col\">Why it matters<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Sample identity and location<\/th><td>Connects the result to the same formulation and production stage<\/td><\/tr><tr><th scope=\"row\">Sample handling<\/th><td>Transfer, vibration or holding time can change the initial packing state<\/td><\/tr><tr><th scope=\"row\">Cylinder diameter and cylinder\/holder mass<\/th><td>Can affect how the powder bed consolidates<\/td><\/tr><tr><th scope=\"row\">Tapping apparatus and endpoint<\/th><td>Drop height, tap count and endpoint can affect the final volume<\/td><\/tr><tr><th scope=\"row\">Powder mass and condition<\/th><td>Supports valid paired calculations and repeatability<\/td><\/tr><tr><th scope=\"row\">Replicate measurements<\/th><td>Helps distinguish an unusual result from routine test variation<\/td><\/tr><\/tbody><\/table><\/div><p>In a 2019 interlaboratory study, Akseli and colleagues found that differences between lots were generally within the variability of the density test. Tapped density and HR showed no significant intersite bias in that study, while bulk density showed marginally significant bias. Record the method and individual readings before interpreting small differences between lots. <sup><a href=\"#ref-akseli\">[2]<\/a><\/sup> For the complete measurement sequence, see the <a href=\"https:\/\/grandgelgumi.com\/tap-density\/\">tapped density measurement guide<\/a>.<\/p><h3>Check unexpected readings before interpreting them<\/h3><p>If tapped density is lower than untapped density, or final tapped volume exceeds initial volume, verify the records, units, sample identity, possible material loss and test procedure. Do not turn an inconsistent reading into an apparently favorable flow classification. If a reading cannot be reproduced, retain the deviation and repeat according to the approved laboratory method.<\/p><\/section>\n<section aria-labelledby=\"same-index\"><h2 id=\"same-index\"><span class=\"ez-toc-section\" id=\"Why_Identical_Hausner_Ratios_Can_Produce_Different_Fill_Weights\"><\/span>Why Identical Hausner Ratios Can Produce Different Fill Weights<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Consider two hypothetical blends with the same HR and CI but different absolute densities. Their relative consolidation is identical; their bulk masses per unit volume are different.<\/p><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Same relative consolidation, different bulk density\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Parameter<\/th><th scope=\"col\">Blend A<\/th><th scope=\"col\">Blend B<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Untapped bulk density<\/th><td>0.500 g\/mL<\/td><td>0.640 g\/mL<\/td><\/tr><tr><th scope=\"row\">Tapped bulk density<\/th><td>0.625 g\/mL<\/td><td>0.800 g\/mL<\/td><\/tr><tr><th scope=\"row\">Hausner ratio<\/th><td>1.250<\/td><td>1.250<\/td><\/tr><tr><th scope=\"row\">Carr index<\/th><td>20.00%<\/td><td>20.00%<\/td><\/tr><tr><th scope=\"row\">Illustrative mass in 1 mL at untapped density<\/th><td>500 mg<\/td><td>640 mg<\/td><\/tr><\/tbody><\/table><\/div><p>At the stated untapped densities, Blend B contains 28% more mass in the same illustrative 1 mL volume. This arithmetic comparison is not a prediction of tablet weight. Real die filling can change with aeration, dosing, feeder operation and consolidation, so the actual difference must be measured on the press.<\/p><p>This is why a useful pre-tableting report retains bulk and tapped density as numerical values rather than recording only the two flow indices. Identical HR and CI readings do not establish identical filling volume, compression behavior or machine suitability.<\/p><\/section>\n<section aria-labelledby=\"press-application\"><h2 id=\"press-application\"><span class=\"ez-toc-section\" id=\"How_Hausner_Ratio_Relates_to_Rotary_Tablet_Press_Performance\"><\/span>How Hausner Ratio Relates to Rotary Tablet Press Performance<span class=\"ez-toc-section-end\"><\/span><\/h2><p>A rotary tablet press fills a defined die cavity, adjusts the quantity of powder, compacts the bed and ejects the tablet. A powder&#8217;s flow behavior and packing state can influence the mass available during filling. Consequently, an unexpected laboratory index may help engineers decide which process conditions to investigate.<\/p><h3>Feeder and turret conditions<\/h3><p>Schomberg, Kwade and Finke studied five formulations on a rotary press and examined how material properties and operating settings influenced filling. Their work found that short filling times at higher turret speeds could cause incomplete filling; paddle speed and dosing conditions could also change the density of the powder in the die. <sup><a href=\"#ref-schomberg\">[3]<\/a><\/sup> These findings support evaluating filling at the intended turret and feeder settings rather than selecting a speed from the flow index alone.<\/p><h3>Investigate the source of tablet weight variation<\/h3><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Using laboratory indices to guide press investigations\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Observation<\/th><th scope=\"col\">Useful next check<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Indices change between batches<\/th><td>Verify comparable sample preparation, density readings and material history<\/td><\/tr><tr><th scope=\"row\">Same HR but tablet mean weight changes<\/th><td>Compare absolute densities, dosing depth and actual feed behavior<\/td><\/tr><tr><th scope=\"row\">Tablet weight spread increases as speed rises<\/th><td>Review available filling time, feeder behavior and recorded settings<\/td><\/tr><tr><th scope=\"row\">Stable weight but different breaking force<\/th><td>Investigate formulation and compression conditions separately<\/td><\/tr><tr><th scope=\"row\">Powder bridges or discharges intermittently<\/th><td>Use an appropriate discharge or shear test and examine hopper conditions<\/td><\/tr><\/tbody><\/table><\/div><p>Changing several settings at once makes it difficult to identify the cause of an observed change. Use an agreed trial plan, record relevant settings, and examine individual tablet weights and variability. Additional checks may include <a href=\"https:\/\/grandgelgumi.com\/tablet-hardness-testing\/\">tablet hardness testing<\/a> and the observations described in our <a href=\"https:\/\/grandgelgumi.com\/tablet-defects\/\">tablet defects guide<\/a>.<\/p><\/section>\n<section aria-labelledby=\"comparison\"><h2 id=\"comparison\"><span class=\"ez-toc-section\" id=\"Hausner_Ratio_vs_Angle_of_Repose_and_Other_Flow_Tests\"><\/span>Hausner Ratio vs. Angle of Repose and Other Flow Tests<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Choose a test based on the problem to be investigated. The Hausner ratio and Carr index describe the relative change in bulk packing under tapping. The angle of repose describes the slope formed by powder under a selected pile-forming method. Discharge and shear tests characterize other aspects of movement and consolidation.<\/p><div class=\"gel-table-wrap\" role=\"region\" aria-label=\"Comparison of powder characterization methods\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Measurement<\/th><th scope=\"col\">Result<\/th><th scope=\"col\">Practical use<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Bulk and tapped density<\/th><td>Mass per apparent bulk volume<\/td><td>Retain absolute values for packing comparisons<\/td><\/tr><tr><th scope=\"row\">Hausner ratio \/ Carr index<\/th><td>Relative consolidation<\/td><td>Screen and compare paired density data<\/td><\/tr><tr><th scope=\"row\">Angle of repose<\/th><td>Slope of powder pile (degrees)<\/td><td>Compare relative resistance to movement under the test method<\/td><\/tr><tr><th scope=\"row\">Flow through an orifice<\/th><td>Discharge behavior or mass flow rate<\/td><td>Investigate flow through an opening<\/td><\/tr><tr><th scope=\"row\">Shear testing<\/th><td>Stress-dependent flow behavior<\/td><td>Investigate cohesive material behavior under defined loads<\/td><\/tr><\/tbody><\/table><\/div><p>In a 2024 comparative study of 21 powders, Tharanon and colleagues found that the pharmacopoeial methods differed in how well they distinguished materials across the flowability range. They recommended using several techniques when feasible. <sup><a href=\"#ref-tharanon\">[4]<\/a><\/sup> When the indices and another flow measurement disagree, check the methods and the handling problem they describe. It may be reasonable for a powder to exhibit limited volume change during tapping yet behave differently through a particular opening. Read our <a href=\"https:\/\/grandgelgumi.com\/angle-of-repose-test\/\">angle of repose test guide<\/a> for cone geometry, measurement procedure and its limitations.<\/p><\/section>\n<section aria-labelledby=\"trial-checklist\"><h2 id=\"trial-checklist\"><span class=\"ez-toc-section\" id=\"Powder_Flow_Records_Before_a_Tablet_Press_Trial\"><\/span>Powder Flow Records Before a Tablet Press Trial<span class=\"ez-toc-section-end\"><\/span><\/h2><p>Prepare a concise material record before discussing equipment. Include representative sample identity, formulation characteristics, both measured densities, calculated HR and CI, the measurement method and repeat results. If the material cannot be disclosed in detail, provide the agreed non-confidential characteristics needed for engineering review.<\/p><p>For the trial itself, agree on target tablet weight and dimensions, production objectives, the proposed machine and tooling configuration, operating records and quality evaluation criteria. Capture any observed feeding interruption or refill event alongside the collected tablet samples.<\/p><h3>Connecting the material record to equipment<\/h3><p>The <a href=\"https:\/\/grandgelgumi.com\/product\/zp31d-rotary-tablet-press\/\">GRAND ZP31D Rotary Tablet Press<\/a> is one example of downstream equipment in the GRAND tablet press range. The laboratory tests discussed here use separate measurement apparatus. Suitability for the intended formulation must be determined from the equipment configuration, tablet specifications and relevant trial evidence, not solely from an HR or CI number.<\/p><figure class=\"gel-article-figure\"><img loading=\"lazy\" class=\"wp-image-4010\" src=\"https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press.webp\" width=\"1000\" height=\"1000\" alt=\"GRAND ZP31D rotary tablet press\" loading=\"lazy\" decoding=\"async\" title=\"\" srcset=\"https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press.webp 1000w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-300x300.webp 300w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-150x150.webp 150w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-768x768.webp 768w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-12x12.webp 12w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-500x500.webp 500w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-600x600.webp 600w, https:\/\/grandgelgumi.com\/wp-content\/uploads\/2026\/08\/ZP31D-Rotary-Tablet-Press-100x100.webp 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure><p>Explore the <a href=\"https:\/\/grandgelgumi.com\/rotary-tablet-press\/\">GRAND rotary tablet press range<\/a> when comparing machines and preparing a technical brief for an equipment trial.<\/p><\/section>\n<section aria-labelledby=\"faq\"><h2 id=\"faq\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2><details name=\"gel-hausner-faq\"><summary>What is a good Hausner ratio for powder flow?<\/summary><p>The referenced relative flow ranking describes 1.12\u20131.18 as good, and 1.00\u20131.11 as excellent. These ranges are descriptive. Actual acceptance criteria depend on the formulation and the validated manufacturing process.<\/p><\/details><details name=\"gel-hausner-faq\"><summary>What is the formula for Carr index?<\/summary><p>CI (%) = 100 \u00d7 (tapped density \u2212 untapped bulk density) \/ tapped density. For volumes measured on the same unchanged sample, use 100 \u00d7 (initial volume \u2212 final tapped volume) \/ initial volume.<\/p><\/details><details name=\"gel-hausner-faq\"><summary>What is the difference between Hausner ratio and Carr index?<\/summary><p>Hausner ratio is dimensionless; Carr index is a percentage. Both are computed from the same paired density or volume readings. Their mathematical relationship is CI = 100 \u00d7 (1 \u2212 1\/HR).<\/p><\/details><details name=\"gel-hausner-faq\"><summary>Can the Hausner ratio be less than 1?<\/summary><p>Under the intended test conditions the tapped volume normally does not exceed the starting volume, so HR should be at least 1. Review the sample and method if a lower value is obtained.<\/p><\/details><details name=\"gel-hausner-faq\"><summary>Does a Carr index of 20% mean the powder can be compressed into tablets?<\/summary><p>No. In the referenced relative ranking, 20% is within the fair-flow band. Tabletability, die filling and finished tablet quality require separate assessment.<\/p><\/details><details name=\"gel-hausner-faq\"><summary>Does the Hausner ratio predict tablet hardness?<\/summary><p>It cannot determine tablet breaking force. Formulation, compaction conditions, tooling and the resulting tablet structure also matter.<\/p><\/details><details name=\"gel-hausner-faq\"><summary>Should I measure both Hausner ratio and Carr index?<\/summary><p>Both can be calculated from one correctly paired set of density readings. Report the original readings and consider independent measurements when the manufacturing question requires more information.<\/p><\/details><\/section>\n<section aria-labelledby=\"conclusion\"><h2 id=\"conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2><p>The Hausner ratio and Carr index provide two ways to express relative powder consolidation from the same bulk and tapped measurements. Calculate them using consistent units and a documented method. Retain the original densities, compare replicate measurements and investigate discrepancies with complementary tests. For a rotary tablet press project, the most useful evidence connects this laboratory record to actual feeding behavior, die filling and tablet quality under documented trial conditions.<\/p><\/section>\n<section aria-labelledby=\"technical-references\"><h2 id=\"technical-references\"><span class=\"ez-toc-section\" id=\"Technical_References\"><\/span>Technical References<span class=\"ez-toc-section-end\"><\/span><\/h2><ol><li id=\"ref-usp\">United States Pharmacopeia. <a href=\"https:\/\/doi.usp.org\/USPNF\/USPNF_M99885_02_01.html\" rel=\"nofollow noopener\" target=\"_blank\">General Chapter &lang;1174&rang; Powder Flow<\/a>. Stage 4 harmonized revision, official May 1, 2024. DOI: 10.31003\/USPNF_M99885_02_01.<\/li><li id=\"ref-akseli\">Akseli I, Hilden J, Katz JM, et al. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/30326209\/\" rel=\"nofollow noopener\" target=\"_blank\">Reproducibility of the Measurement of Bulk\/Tapped Density of Pharmaceutical Powders Between Pharmaceutical Laboratories<\/a>. Journal of Pharmaceutical Sciences. 2019;108(3):1081\u20131084. DOI: 10.1016\/j.xphs.2018.10.009.<\/li><li id=\"ref-schomberg\">Schomberg AK, Kwade A, Finke JH. <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC7150958\/\" rel=\"nofollow noopener\" target=\"_blank\">The Challenge of Die Filling in Rotary Presses\u2014A Systematic Study of Material Properties and Process Parameters<\/a>. Pharmaceutics. 2020;12(3):248. DOI: 10.3390\/pharmaceutics12030248.<\/li><li id=\"ref-tharanon\">Tharanon W, Guo Y, Peerapattana J, Sun CC. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/38986964\/\" rel=\"nofollow noopener\" target=\"_blank\">A systematic comparison of four pharmacopoeial methods for measuring powder flowability<\/a>. International Journal of Pharmaceutics. 2024;661:124454. DOI: 10.1016\/j.ijpharm.2024.124454.<\/li><\/ol><\/section><\/article>\n","protected":false},"excerpt":{"rendered":"<p>Calculate the Hausner ratio and Carr index from bulk and tapped density, interpret flow results, and prepare your powder data for a tablet press trial.<\/p>","protected":false},"author":7,"featured_media":6476,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17],"tags":[],"class_list":["post-6471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-insights"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/posts\/6471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/comments?post=6471"}],"version-history":[{"count":4,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/posts\/6471\/revisions"}],"predecessor-version":[{"id":6475,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/posts\/6471\/revisions\/6475"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/media\/6476"}],"wp:attachment":[{"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/media?parent=6471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/categories?post=6471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/grandgelgumi.com\/ko\/wp-json\/wp\/v2\/tags?post=6471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}